Home / Industries / Hospitals

HOSPITALS & HEALTHCARE

Fire Safety Equipment for Hospitals, Nursing Homes & Clinics

Hospital fires start in the places patients can least afford them: ICUs on oxygen, operation theatres, crowded wards. MANXPOWER supplies ISI-certified fire safety equipment for hospitals across India, and complete fire safety for nursing homes and clinics, from CO₂ extinguishers beside ventilators to alarm panels for every floor, matched zone by zone to what your Fire Safety Officer and NOC inspector will check.

ISO 9001:2015 Certified Firm · Est. 2015 · New Delhi · Supplying Hospitals Across India

Spec View
MANXPOWER CO₂ fire extinguisher for hospital ICU and electrical rooms
CO₂ · 4.5 KG

Leaves no powder or residue, so it suits use around ventilators, monitors and ICU electrical panels. ISI-certified (IS 15683).

What fire safety equipment does a hospital need?

A hospital needs residue-free CO₂ extinguishers in ICUs, OTs and electrical rooms; non-toxic water-based extinguishers in wards and OPD; ABC units for generator rooms and stores; a fire alarm system with smoke detectors on every floor; hose reels or hydrants on each floor; and a valid fire NOC. MoHFW’s 2026 guidelines add a Fire Safety Officer and an annual fire and electrical audit.

ISO
9001:2015 Certified
ISI
Certified Extinguishers
IS 2190:2024

Placement Guidance

ICU & OT

Ready Range

Pan-India

Supply

Since

2015

THE RISK

Why Hospital Fires Are Different

In most buildings, the rule in a fire is simple: get everyone out. In a hospital, many patients can’t walk, some are on ventilators, and newborns can’t be carried out ten at a time. That is why hospital fire safety in India is planned around defending patients in place and moving them sideways to a safe zone, not just evacuating.

India’s Health Ministry describes hospitals as high-risk buildings because of heavy electrical loads, oxygen-rich settings and complex medical equipment.MoHFW, National Guidelines on Fire and Life Safety in Healthcare Facilities, 2026

Three things make a hospital fire worse than an ordinary building fire:

1
Oxygen-enriched air.Oxygen does not burn, but it makes everything else burn faster and hotter. Research on ICU fires notes that a rise from the normal 21% to just 24% oxygen in room air already creates a fire hazard, and you cannot see or smell it.
2
Heavy, round-the-clock electrical load.Ventilators, monitors, warmers, infusion pumps and AC units often share old circuits in ICUs that never switch off.
3
Patients who can’t self-evacuate.ICU, NICU, OT and post-op patients need staff to move them, so every minute of early warning matters.

Recent hospital fires in India

DateHospitalAreaSuspected causeDeaths
5 Oct 2025SMS Hospital, JaipurTrauma Neuro ICU (fire began in storage area)Short circuit6 per hospital; NHRC cited reports of 8
15 Nov 2024Maharani Laxmi Bai Medical College, JhansiNICUOxygen concentrator short circuit10 newborns
25 May 2024Baby Care New Born Hospital, Vivek Vihar, DelhiNewborn careOxygen cylinder blast suspected by fire services; licence had expired7 newborns
6 Nov 2021District hospital, AhmednagarCovid ICUFire in ICU11
23 Apr 2021Vijay Vallabh Hospital, VirarICUICU blaze15
9 Jan 2021District General Hospital, BhandaraSick Newborn Care Unit (SNCU)Short circuit10 newborns
6 Aug 2020Shrey Hospital, AhmedabadICUICU blaze8

Sources: Al Jazeera, Jhansi · Scroll/PTI, Jaipur · NHRC · Deccan Herald, Vivek Vihar · Scroll/PTI, Bhandara · Business Standard · PMC, oxygen fires

KNOW THE IGNITION SOURCES

Fire Hazards in Hospitals and Nursing Homes: What Causes Them?

Most hospital fires begin with something routine: a tired circuit, a leaking oxygen fitting, a cluttered store next to an ICU. These are the sources we plan equipment around.

Oxygen concentrators and medical gas

Faulty concentrators, worn regulators and leaking pipeline outlets raise oxygen levels around the bed.

ICU and NICU electrical overload

Ventilators, warmers, monitors and pumps on shared sockets and extension boards, running 24×7.

Stores beside critical care

Paper, packaging, plastic tubing and spare equipment stacked next to patient areas feed a fire fast.

Operation theatres

Electrosurgery and lasers, alcohol-based skin prep and oxygen at the face: all three sides of the fire triangle in one place.

Pharmacy and laboratories

Spirits, solvents, reagents and gas burners, often stored in small rooms with poor ventilation.

Air conditioning and ducts

Sealed wards depend on AC units whose compressors and wiring overheat.

Kitchens and pantries

LPG, hot oil and steam in patient diet kitchens and staff canteens.

Generator, UPS and electrical rooms

Diesel sets, battery banks and panels that keep life support running during outages.

MATCH THE EQUIPMENT TO THE ZONE

Fire Extinguisher in Hospital: Which Type Goes in Each Area?

Near patients, the wrong extinguisher can cause harm of its own. Dry powder, for example, leaves a fine, corrosive dust that irritates the lungs and can damage electronic equipment. CO₂ leaves no residue but displaces oxygen, so in a small, closed room use short bursts and ventilate afterwards. Find the zone, then the equipment.

Fire classes (Indian Standard): A = solids such as wood, paper, cloth and plastics · B = flammable liquids · C = flammable gases such as LPG · D = metals · F = cooking oils and fats. Electrical equipment is not a separate class: pick an extinguisher tested for live electrical use, such as CO₂.

Hospital zoneWhat is thereRecommended equipment
ICU, NICU, HDUPatients on oxygen, ventilators, warmers, monitorsCO₂ extinguisher (2 kg) at each nurse station; smoke detectors on a zoned alarm panel. Prefer CO₂ over dry powder inside the unit.
Operation theatresElectrosurgery, oxygen, alcohol prep, drapesCO₂ extinguisher just outside each OT; heat or smoke detection in the OT complex; fire blanket for clothing and drape fires
Wards and patient roomsBedding, curtains, furniture, personal chargers9 litre water-based extinguisher (non-toxic) per wing for Class A fires only, never on electrical equipment; CO₂ where bedside equipment is used; smoke detectors; manual call points at exits
Oxygen manifold and cylinder storeStored cylinders, manifold, pipeline valvesABC or CO₂ at the entry, never inside; keep oils and grease away; clear “No Smoking / No Oil” signs
Electrical, UPS, server and DG roomsPanels, batteries, dieselCO₂ for panels; ABC for the DG set and fuel
Pharmacy and laboratoriesSpirits, solvents, reagents, burnersCO₂ for lab benches; ABC for spirit stores; gas detector where burners run on LPG
Kitchen and pantryLPG, cooking oilFire blanket + ABC extinguisher; gas detector for LPG leaks
Medical records, linen, storesPaper, cloth, cartonsWater-based or ABC extinguisher; smoke detectors; concealed sprinklers where required
OPD, corridors, staircasesLarge crowds, wheelchairs, stretchersHose reel drums per floor; alarm hooters and manual call points; extinguishers at each landing
MRI suiteStrong magnetic fieldOrdinary extinguishers are ferromagnetic and can be pulled into the magnet. Keep them outside the MRI room; inside, use only extinguishers marked MR Safe (non-magnetic). Plan with your MRI safety officer.

Final type, size, count and placement must follow IS 2190:2024, your Fire Safety Plan and your local fire authority. This table is a starting point, not a site assessment.

How to Choose a Fire Extinguisher for a Hospital: 5 Steps

  1. List what can burn in each zone: solids, flammable liquids, gas, live electrical equipment or cooking oil.
  2. Match the type to the fire: water for Class A solids only; CO₂ for electrical equipment and liquids; ABC for mixed risks away from patients; a fire blanket for kitchen and clothing fires.
  3. Check the space: near patients and equipment, prefer residue-free CO₂; in small, closed rooms plan ventilation; in MRI rooms use only MR Safe units.
  4. Check the mark and placement: ISI-certified to IS 15683, with size and placement set out in IS 2190:2024.
  5. Plan the upkeep: inspect and service as IS 2190:2024 sets out, refill after any use, and record it for your Fire Safety Officer’s annual audit.
WHAT WE SUPPLY

Hospital Fire Safety Equipment We Supply

ISI-certified extinguishers and fire safety equipment from MANXPOWER and the brands we distribute, supplied for a single nursing home or a multi-block hospital.

CO₂ extinguishers

2 kg and 4.5 kg. Residue-free for ICUs, OTs, labs and electrical rooms.

Water-based extinguishers

9 litre, non-toxic. For Class A fires in wards, OPD, offices and records. Never use on electrical fires.

ABC extinguishers

1 kg to 9 kg. For generator rooms, stores, kitchens and oxygen-store entrances.

Fire alarm system for hospitals

Conventional 2 to 16 zone panels, detectors, call points and hooters for every floor.

Standalone smoke and gas detectors

No wiring. Suited to small clinics, staff quarters and as add-ons. They do not replace the alarm system a hospital is required to have.

Hose reel drums and hydrant valves

First-aid firefighting on every floor. MoHFW’s 2026 guidelines list hydrants and hose reels among required hospital fire-safety infrastructure.

Concealed sprinklers

Ceiling-flush heads for wards, corridors and lobbies where appearance matters.

Fire blankets

1 m × 2 m, for OT drape and clothing fires and pantry stoves.

COMPLIANCE

Hospital Fire Safety Rules in India: What Your Inspector Checks

Hospital inspections no longer stop at “are extinguishers on the wall?”. Under the 2026 national guidelines, inspectors and NABH assessors look for a named Fire Safety Officer, a live hazard register, drill records and equipment that is in date. We supply against the standards they cite.

Guidelines and NOC rules vary by state and are revised from time to time. Confirm current requirements with your local fire authority and NABH before relying on this page.

MoHFW National Guidelines, 2026Issued in 2026, revising the 2020 guidelines. Hospital management is responsible for compliance. Every facility should have a Fire Safety Committee and a designated Fire Safety Officer, assess fire hazards at least every quarter, keep a Fire Hazard Register, and run an annual fire audit that includes electrical safety (third-party audit recommended). ICU, OT and security staff get specialised evacuation training. The guidelines cover hospitals, nursing homes, maternity and childcare centres and other healthcare facilities. For hospitals taller than 15 m, the Fire Safety Officer should be a qualified professional with at least three years’ fire-safety experience; this is also recommended for facilities with 250 or more beds.
NBC 2016, Part 4Hospitals fall under Group C, Institutional occupancy. Sets fire detection, extinguishers, hose reels, hydrants, sprinklers and exit requirements by height and area. Being revised as NBCS 2026.
State Fire NOCIssued by the State Fire Services Department under state fire rules. Height and bed-count thresholds vary by state.
NABH accreditationExpects a valid fire NOC as applicable. Where the NOC is pending, NABH accepts a Fire & Life Safety certificate from an NABCB-accredited inspection body for accreditation only; it does not replace the statutory NOC. Mock drill records and schedules are checked.
NQAS (public health facilities)Guidance for public facilities calls for a fire mock drill at least once every quarter.
Indian Standards
IS 2190:2024Selection, installation and maintenance of portable and mobile first-aid extinguishers.
IS 15683:2018Portable fire extinguishers; the ISI mark certifies to this.
IS 2189:2026Automatic fire detection and alarm systems.
IS 15105:2021Fixed automatic sprinkler systems.
IS 3844:1989Internal hydrants and hose reels.
IS 884First-aid hose reels (IS 884:2025, second revision, replaces IS 884:1985).

Sources: MoHFW 2026 guidelines summary, TeamLease RegTech · NABH fire safety advisory · NABH clarification · NHSRC NQAS guidance · BIS IS 2190:2024 · BIS IS 2189:2026 · BIS IS 884:2025

WHY MANXPOWER

Built for Hospitals That Never Close

MANXPOWER is the fire safety brand of Manx Impex, an ISO 9001:2015 certified supplier based in New Delhi since 2015.

01

The right agent near patients

We steer powder away from ICUs and OTs and specify residue-free CO₂ where patients and equipment are.

02

Audit-ready paperwork

ISI certificates, invoices and refill dates in one set, so your FSO’s file and NABH binder are easy to update.

03

Zone-wise planning

Quotes are built ward by ward, ICU by ICU, not as a single bulk number.

04

One vendor, whole building

Extinguishers, detectors, alarm panels, hose reels and sprinklers on one quote and one invoice.

05

Hospital groups and chains

One quote across several hospitals, nursing homes or diagnostic centres.

06

Refills timed to your audit

Refilling and service reminders scheduled so nothing lapses before the annual fire audit.

HOW IT WORKS

Equipping Your Hospital in Four Steps

01

Share your hospital details

Floors, bed count, ICU/NICU and OT locations, oxygen manifold position and current equipment list.

02

Zone mapping

We map each zone to the right equipment, with your FSO or biomedical engineer, against IS 2190 and your state’s fire rules.

03

Itemised quote

Products, quantities and placement per zone, with certificates listed.

04

Supply and refill calendar

Dispatch across India, installation support, and a refill schedule aligned to your audit date.

GET A QUOTE

Protect Your Patients, Your Staff and Your Critical Care Units

Tell us your facility type (hospital, nursing home, clinic or diagnostic centre), bed count and what is already installed. We’ll send an itemised, zone-wise quote and flag anything your fire audit is likely to question.

AddressManx Impex, 3963/9, Ground Floor, City Market, Ajmeri Gate, New Delhi 110006
HoursMon–Sat, 10:30 AM – 5:00 PM · Sunday closed
This field is required.
This field is required.
This field is required.
This field is required.
This field is required.

ANSWERS

Hospital Fire Safety: Frequently Asked Questions

Hospitals use three types by zone: CO₂ in ICUs, OTs, labs and electrical rooms; water-based in wards and offices; ABC in generator rooms, stores and kitchens. PGIMER Chandigarh, for example, runs over 2,500 extinguishers, mainly ABC and CO₂.

Use CO₂. It leaves no powder residue, which irritates lungs and corrodes ventilators and monitors. In a small, closed room, use short bursts and ventilate afterwards, since CO₂ displaces oxygen. Keep a fire blanket in the OT.

Oxygen does not burn, but extra oxygen makes bedding, tubing and even fire-resistant materials ignite easily and burn hotter. A rise from the normal 21% to about 24% is already a hazard, and you cannot see or smell it.

Most hospitals and many nursing homes need a fire NOC from the State Fire Services Department. Height, area and bed-count thresholds differ by state, so some small clinics may be exempt. Check your state’s rules and renew before it lapses.

NABH expects a valid fire NOC where applicable, a fire safety plan, trained staff, working equipment and mock drill records. If the NOC is pending, an NABCB-accredited inspection certificate is accepted for accreditation only; it never replaces the statutory NOC.

A Fire Safety Committee, a designated Fire Safety Officer, quarterly fire hazard assessments recorded in a Fire Hazard Register, and an annual fire audit that includes electrical safety. Third-party audits are recommended. They cover hospitals, nursing homes and other healthcare facilities.

At least once a quarter, including a mock evacuation of ICU or NICU patients. Public facilities following NQAS guidance drill quarterly, and NABH assessors check drill records and schedules.

Typically CO₂ and water-based extinguishers on every floor, smoke detectors in patient rooms, a fire blanket in the pantry and clear exit signs. Larger homes may need an alarm panel and hose reels. MoHFW’s 2026 guidelines apply to nursing homes too.