Home / Factories

FACTORIES

Fire Safety Equipment for Factories & Industrial Plants

From a single machine shop to a multi-shed manufacturing plant — MANXPOWER supplies ISI-certified, UL-listed fire and industrial safety products across India, backed by compliance guidance and dependable after-sales support.

ISO 9001:2015 Certified Firm  ·  Est. 2015 · New Delhi  ·  Supplying Across India

Spec View
ABC
ABC Dry Powder · 9 KG

Portable extinguisher, stored-pressure type. Placement, size and count per IS 2190:2024 and the local fire authority.

ISO
9001:2015 Certified
ISI
Certified Products
UL
Listed Products
2015
Trusted Since
PAN
India Supply
OEM

Multi-Brand Range

THE RISK

A factory fire doesn't wait for your next audit

Hot work near stored packaging. An overloaded panel behind a machine. Dust in an extraction duct. In a working plant the ignition sources are ordinary, constant and spread across every shed — which is why fire protection is treated in Indian law as a standing obligation, not a one-time purchase.
"In every factory, all practicable measures shall be taken to prevent outbreak of fire and its spread… and to provide and maintain safe means of escape for all persons and the necessary equipment and facilities for extinguishing fire." The Factories Act, 1948 — Section 38(1)
5,971fire accident casesrecorded nationally in 2024
5,888lives lost to firein the same year
149fire cases in factoriescombined across both factory categories, 188 deaths

Source: NCRB, Accidental Deaths & Suicides in India (ADSI) 2024, Table 1.12 — ncrb.gov.in. "149" sums the "Factory — Combustible Materials" (66) and "Other Factories" (83) rows; cite the table, not a single line.

KNOW THE IGNITION SOURCES

Common causes of fire in factories

Protection only works when it is matched to how fires actually start on your floor. These are the recurring sources we size equipment against.

Electrical Overload

Overloaded circuits, ageing cabling and short circuits inside distribution panels.

Machinery Overheating

Friction, seized bearings and continuous-duty motors running without cool-down.

Hot Work

Welding, grinding and cutting sparks landing on stock, waste or packaging.

Combustible Dust

Wood, flour, textile lint and metal dust accumulating in ducts and on beams.

Flammable Liquids

Solvents, thinners, paints, diesel and lubricants stored close to the line.

Loose Connections

Arcing at terminals and busbars — often invisible until the panel is already alight.

Static Discharge

Ungrounded transfer of powders and solvents generating an ignition spark.

Skipped Maintenance

Expired refills, blocked hydrants and extinguishers nobody has checked in months.

MATCH THE AGENT TO THE HAZARD

Which fire protection does your plant need?

The wrong extinguishing agent can spread a fire instead of stopping it. Find your hazard, then the equipment that belongs next to it.
Fire ClassWhat Burns in Your PlantRecommended Equipment
ASolidsWood, paper, cartons, textiles, packaging, rubber, plastics, stored finished goods.ABC dry powderWater / water-CO₂ for bulk storage areas.
BLiquidsDiesel, petrol, solvents, thinners, paints, oils, lubricants, chemical storage.AFFF mechanical foamABC dry powder or CO₂ as the situation requires.
CGasesLPG, CNG, acetylene and other flammable process or fuel gases.ABC dry powderPlus gas detection and isolation at source.
DMetalsMagnesium, aluminium and titanium swarf in fabrication, casting and machining.Class D special powderNever water or standard ABC on metal fires.
ELive Equip.Control panels, MCC rooms, server racks, UPS banks, energised machinery.CO₂ or clean agentResidue-free — no damage to electronics.
KCookingCanteen and staff-kitchen deep fryers, cooking oils and fats.Wet chemicalKitchen hood suppression where fitted.
AreaWhole ShedLarge production halls, warehouses, high-rack storage and covered yards.Hydrant, hose reels, sprinklersWith detection and alarm coverage.

Final selection, placement and quantity must follow IS 2190:2024 and your local fire authority — this table is a starting point, not a substitute for a site assessment.

WHAT WE SUPPLY

Fire & industrial safety products for factories

ISI-certified and UL-listed equipment from MANXPOWER and the brands we distribute — available as single units or as a full plant-wide package.

Fire Extinguishers

ABC dry powder, CO₂, foam, clean agent — 1 kg to 9 kg portable and trolley-mounted units.

Extinguisher Accessories

Mounting brackets, hoses and spares to keep every extinguisher ready to use.

Extinguishing Agents

ISI-certified refill agents across every fire class your plant carries.

Hydrant Valves & Fittings

Landing valves, couplings, branch pipes and nozzles for internal and yard hydrant networks.

Hose Reel Drums

First-aid hose reel drums and accessories for fast, organised deployment.

Sprinkler Systems & Hoses

Flexible sprinkler hoses for fast, code-compliant shed-wide coverage.

Conventional Alarm Systems

Reliable zone-based detection panels for early warning across every shed.

Standalone Alarm Systems

Battery-powered standalone alarms for instant fire and smoke detection.
COMPLIANCE

Factory fire safety in India, made simple

A factory inspection rarely turns on whether you own equipment — it turns on whether the right equipment is installed, marked, accessible and in service. We supply against the standards your inspector will actually cite.
Requirements and NOC validity vary by state and are revised periodically. Confirm current requirements with your local fire authority before relying on this page.
Statute & Code
Factories Act 1948Section 38 — precautions in case of fire; means of escape and firefighting equipment.
NBC 2016, Part 4Fire and Life Safety. Industrial buildings fall under Group G occupancies.
State Fire NOCIssued by the State Fire Services Department; assessed against NBC and state fire rules.
Indian Standards
IS 2190:2024Selection, installation & maintenance of first-aid fire extinguishers — portable and mobile. Fifth revision, supersedes IS 2190:2010.
IS 15683:2018Portable fire extinguishers — performance and construction. The ISI mark certifies to this.
IS 2189:2008Automatic fire detection and alarm systems — code of practice.
IS 3844:1989Internal fire hydrants and hose reels on premises — installation and maintenance.
IS 15105:2021Design and installation of fixed automatic sprinkler systems.
IS 5290:2025Landing valves for firefighting installations — specification.
IS 636:2018Non-percolating flexible firefighting delivery hose — specification.
IS 884:1985First-aid hose-reel for firefighting — specification.
WHY MANXPOWER

Built for plants that can't afford downtime

01

Certified Products Only

ISI-certified and UL-listed equipment, supplied with the documentation your inspector and insurer will ask for.
02

Delhi Base, All-India Supply

Dispatch from our Ajmeri Gate warehouse to plants across India, single units or bulk orders.
03

One Vendor, Full Scope

Extinguishers, hydrants, hoses, alarms and detectors under one quote, one invoice, one point of contact.
04

Compliance Guidance

We help you map IS 2190 and NBC requirements to your layout before you buy, not after a notice arrives.
05

Refilling & After-Sales

Ongoing refilling and service support so your extinguishers stay in date between inspections.
06

Trusted Since 2015

An ISO 9001:2015 certified firm supplying industrial and fire safety products across India.
HOW IT WORKS

Equipping your plant in four steps

01

Share Your Layout

Send your shed plan, process list and current equipment inventory — or request a site visit.
02

Hazard Assessment

We map your hazards to fire classes and to what IS 2190 and NBC 2016 require for your occupancy.
03

Compliant Quote

An itemised quote with certified products, quantities, placement and documentation included.
04

Supply & Support

Dispatch across India, installation support, and refilling reminders so nothing lapses.
ANSWERS

Factory fire safety — frequently asked

Most factories need a mix: ABC dry powder for general solid/liquid/gas risk, CO₂ or clean agent near live electrical panels, and Class D powder wherever combustible metal swarf or dust is present. The right mix depends on what’s stored and processed on your floor.

IS 2190:2024 and your local fire authority set the count based on floor area, occupancy and hazard class — not a fixed “one per X sq ft” rule. We size this against your actual layout during a hazard assessment.

Section 38 of the Factories Act, 1948 requires every factory to take practicable measures to prevent fire, and to provide and maintain safe escape routes and firefighting equipment. A related clause requires workers to be trained in the escape routine.

Most states require a Fire No-Objection Certificate from the State Fire Services Department before occupancy, assessed against NBC 2016 and state-specific fire rules. Requirements and renewal cycles vary by state — check with your local fire authority.

IS 2190:2024 sets inspection and recharge intervals by extinguisher type — typically annual servicing with recharge on discharge or expiry. We offer refilling and after-sales support so nothing lapses between statutory checks.

Yes — we dispatch pan-India from our Ajmeri Gate, New Delhi warehouse, for single units and bulk plant-wide orders alike.

GET A QUOTE

Protect your plant, your people and your production

Tell us your facility type and what you already have installed. We’ll come back with an itemised, compliance-ready quote — and flag anything your current setup is missing.
AddressManx Impex, 3963/9, Ground Floor, City Market, Ajmeri Gate, New Delhi 110006
Phone+91 11 4987 2937
Emailinfo@manximpex.com
HoursMon–Sat, 10:30 AM – 5:00 PM · Sunday closed
This field is required.
This field is required.
Scroll to Top