EDUCATIONAL INSTITUTES
Fire Safety Equipment for Schools, Colleges & Hostels
From a single-building school to a multi-block college campus with hostels and labs, MANXPOWER supplies ISI-certified fire extinguishers, detectors, alarm systems and hose reels across India, with guidance on what your fire NOC inspection will check.
ISO 9001:2015 Certified Firm · Est. 2015 · New Delhi · Supplying Across India


Portable extinguisher for Class A fires. Non-toxic and ISI-certified (IS 15683), so it is safe to use in classrooms, libraries and offices.
What fire safety equipment does a school need?
A school needs ISI-certified fire extinguishers on every floor (water-based for classrooms, CO₂ for computer and science labs, a fire blanket and ABC for kitchens, ABC or CO₂ for electrical rooms), smoke detectors in hostels, an alarm system in main blocks, and a fire NOC from the State Fire Services Department.
Multi-Brand Range
A School Fire Doesn’t Wait for the Next Drill
An overloaded socket in a hostel room. A spark in the chemistry lab. Cooking oil in the canteen. On a campus the ignition sources are ordinary, spread across many buildings, and the people in them are mostly young. That is why schools and colleges must plan for fire as a standing responsibility, not a one-time purchase.
After Kumbakonam, the Supreme Court of India (13 April 2009) directed that schools install fire extinguishing equipment, train their staff to use it and meet National Building Code norms. Its minimum safety standards for schools include a fire safety inspection and NOC, mock drills and periodic inspections.Supreme Court of India, 13 April 2009
Source: NCRB, Accidental Deaths & Suicides in India (ADSI) 2024, Table 1.13 – ncrb.gov.in; Kumbakonam verdict: Al Jazeera, 30 July 2014; Supreme Court of India, Avinash Mehrotra v. Union of India, 13 April 2009.
What Causes Fires in Schools and Colleges?
Protection only works when it matches how fires actually start on your campus. These are the recurring sources we size equipment against.
Electrical overload
Air conditioners, projectors, smart boards and computer labs on old wiring or shared circuits.
Science labs
Burners, solvents and reagents used by students with varying supervision.
Canteen and kitchen
LPG cylinders, hot oil and exhaust ducts in mess and canteen kitchens.
Hostel rooms
Chargers, heaters, kettles and extension boards running overnight.
Libraries and records
Paper, files and wooden shelving that feed a small fire quickly.
Workshops and hot work
Welding, grinding and machining in engineering, ITI and maintenance sheds.
Generator and server rooms
Diesel sets, UPS banks and network racks close to occupied buildings.
Skipped maintenance
Expired refills and extinguishers nobody has checked since the last inspection.
MATCH THE EQUIPMENT TO THE AREA
Which Fire Protection Does Your Campus Need?
The wrong extinguisher can do more harm than good. Find the area, then the equipment that belongs there.
Fire classes (Indian Standard): A = solids such as wood, paper, cloth and plastics · B = flammable liquids · C = flammable gases such as LPG · D = metals · F = cooking oils and fats. Electrical equipment is not a separate class: pick an extinguisher tested for live electrical use, such as CO₂.
| Area | What is there | Recommended equipment |
|---|---|---|
| AClassrooms & offices | Desks, books, paper, cloth, wooden furniture, staff rooms and libraries. | 9 litre water-based extinguisherNon-toxic and ISI-certified (IS 15683). Add a CO₂ unit where smart boards or projectors are installed. |
| A BComputer & science labs | Live electrical equipment, computers, solvents and chemicals. | CO₂ extinguisherLeaves no residue, so lab equipment is not damaged. |
| F CCanteen & kitchen | Cooking oil, LPG and stoves, with a risk of small pan and gas fires. | Fire blanket + ABC extinguisherThe blanket smothers pan and cooking-oil fires. Keep the ABC extinguisher for other kitchen fires. Plus a gas detector to warn of LPG leaks. |
| AHostel rooms & dormitories | Bedding, chargers, heaters and extension boards, with students asleep. | Standalone smoke detectorsNo wiring needed. Sounds the alarm early, even at night. |
| AMain blocks & corridors | Classroom wings, auditoriums and staircases where many people move at once. | Conventional alarm panel + detectorsZone-based panel (2 to 16 zones) with detectors, call points and hooters. Plus hose reel drums on each floor for first-aid firefighting. |
| BGenerator & electrical rooms | Diesel generators, panels and UPS banks. | ABC or CO₂ extinguisherNever use water on live electrical panels. |
Final selection, placement and quantity must follow IS 2190:2024 and your local fire authority — this table is a starting point, not a substitute for a site assessment.
Fire Safety Products for Schools and Colleges
Water-based extinguishers
9 litre, non-toxic and ISI-certified. Built for classrooms, libraries and offices.
ABC & CO₂ extinguishers
ABC in 1 kg to 9 kg, CO₂ in 2 kg and 4.5 kg. For labs, generator rooms, kitchens and workshops.
Fire blankets
1 m × 2 m fire-retardant fibreglass blankets for lab benches and canteen stoves.
Standalone alarms
Smoke, gas and CO detectors with no wiring, suited to hostel rooms and staff quarters.
Conventional alarm systems
Zone-based panels, detectors, call points and hooters for main blocks and hostels.
Hose reel drums
First-aid hose reel drums with UL-listed flexible hoses, for fast, organised response on each floor.
Concealed sprinklers
Ceiling-flush sprinklers for auditoriums, libraries and administrative blocks.
Gas detectors
LPG and natural gas monitoring for canteens, hostel kitchens and chemistry labs.
Campus Fire Safety in India, Made Simple
An inspection rarely turns on whether you own equipment. It turns on whether the right equipment is installed, marked, accessible and in service. We supply against the standards your inspector will actually cite.
Requirements and fire NOC rules vary by state and are revised periodically. Confirm current requirements with your local fire authority before relying on this page.
Built for Campuses That Can’t Afford a Missed Inspection
MANXPOWER is the fire safety brand of Manx Impex, an ISO 9001:2015 certified firm based in New Delhi since 2015.
Certified extinguishers
ISI-certified to IS 15683, supplied with the documentation your inspector will ask for.
Safe around students
Non-toxic water-based extinguishers for classrooms, and the right agent for labs and kitchens.
One vendor, full scope
Extinguishers, detectors, alarms, hose reels and sprinklers under one quote, one invoice, one contact.
All-India supply
Dispatch from New Delhi to campuses across India, single units or bulk orders.
Multi-campus orders
School groups, trusts and universities can quote several branches together.
Refilling & after-sales
Refilling and service support so your extinguishers stay in date between inspections.
Equipping Your Campus in Four Steps
Share your campus details
Send your building list, floors, labs, hostels and current equipment, or request a site visit.
Equipment planning
We match each area to the right equipment and to what your state fire authority expects.
Itemised quote
Certified products, quantities, placement guidance and documentation in one quote.
Supply & dispatch
Dispatch across India, plus installation support and refilling reminders so nothing lapses.
School and Campus Fire Safety: Frequently Asked
Most schools need a mix. A 9 litre water-based extinguisher is non-toxic and suits classrooms, libraries and offices. Use CO₂ in computer and science labs, a fire blanket and ABC extinguisher in kitchens, and ABC or CO₂ in generator and electrical rooms.
There is no fixed number per room. IS 2190 and your local fire authority set the count based on floor area, occupancy and hazard, with extra units for labs, kitchens and electrical rooms. Share your floor plan and we will size it for your buildings.
Yes, in most cases. The Supreme Court’s 2009 judgment sets minimum safety standards for schools that include a fire safety inspection and NOC, and CBSE bye-laws require schools to follow state fire safety rules. Colleges and hostels need one under state fire rules. Thresholds and renewal cycles vary by state, so check with your local fire authority.
Standalone smoke detectors need no wiring and sound an alarm in the room itself, which suits hostel rooms and staff quarters. For larger blocks, a conventional panel with detectors, call points and hooters covers whole zones.
Check every extinguisher visually once a month for pressure, seal and damage, and get it serviced by a qualified technician at least once a year. Refill it immediately after any use. IS 2190 sets the detailed maintenance intervals for each type. We offer refilling and service support.
Yes. We quote multi-campus orders together for school groups, trusts and universities. Share your locations and quantities.
Yes. We dispatch from New Delhi to schools and colleges across India.
Protect Your Students, Your Staff and Your Campus
Tell us your institute type and what you already have installed. We will come back with an itemised quote and flag anything your inspector is likely to question.